  • Electrical Tester measures AC/DC voltage up to 1000V, 600A AC Current, 60MOhms Resistance, DC millivolts and microamps
  • Amp Clamp with automatically ranging True Root Mean Squared (TRMS) measurement technology for accuracy CAT IV 600V, CAT III 1000V, Class 2, Double insulation safety rating
  • Clamp measures AC current and inrush current
  • Two K-Type thermocouple ports for differential temperature measurements
  • Test leads measure AC/DC voltage, DC microamp, resistance, LoZ, continuity, frequency, duty-cycle, capacitance, and diodes
  • Dedicated mode for capturing DC microamp and inrush current
  • Low-Pass filter and Low impedance (LoZ) mode for identifying and eliminating ghost or stray voltages
  • Dual backlit 6000 LCD display for clear visibility in environments with low ambient lighting
  • Rugged design with a 6.6-Foot (2 m) drop protection and a CAT IV 600V Safety Rating
  • Includes carrying case, instruction manual, straight input test leads, two K-type thermocouples, and 3 x AAA batteries
  • Can be used with Magnetic Hanger Cat. No. 69417 (sold separately)
  • Use with K-Type Temperature Pipe Clamp Cat. No. 69140, and K-Type Temperature Probe Cat. No. 69144 (sold separately)
ce Product Icon
etl-intertek Product Icon
Videos
Downloads
Images
High-Res JPG
PNG

ÀÇÓÑÉçÇø CL450 Clamp Meter with dual display is a ''game changer'' for the HVAC professional. It measures AC/DC voltage up to 1000V, 600A AC Current, 60MΩ Resistance, DC millivolts and microamps. This True RMS CAT IV 600V meter offers differential temperature, digital temperature calibration, inrush current and many other functions for HVAC applications.

Specifications
Type:
HVAC Clamp Meter with Differential Temperature
Application:
HVAC
Special Features:
Differential Temperature with Digital Temperature Calibration; Dedicated Mode for Capturing DC microamp and Inrush Current; Integrated Non-Contact Voltage Tester; Low-pass Filter and Low Impedance (LoZ) Mode; AC and DC Voltage
Material:
Plastic/Electronics
Batteries:
3 x AAA
Auto-Power Off:
Yes
Jaw Size:
2'' (5 cm)
Drop Protection:
6.6' (2 m)
Display:
6000 Count LCD
Functions:
Differential Temperature, Digital Temperature Calibration, DC microamp, Inrush Current, Audible Continuity, Capacitance, Diode Test, Frequency and Duty Cycle, Low-pass Filter, Low Impedance, AC and DC Current, Min/Max, AVG, Data Hold Capability
Voltage:
1000V AC; 1000V DC
Frequency:
999.9kHz
Current:
600A AC
Capacitance:
6000µ¹ó
Ohms (Resistance):
60²ÑΩ
AC Voltage:
1000
DC Voltage:
1000
DC Polarity Indicator:
Y
DC Micro-Amp:
200 μA with 1μA Resolution
Temperature Range:
-40° to 1832°F (-40° to 1000°C)
Standard:
CATIV 600V, CATIII 1000V
Included:
Carrying Case, Instruction Manual, Straight Input Test Leads, Two K-type Thermocouples, and 3 x AAA Batteries
Overall Length:
10.00'' (25.4 cm)
Overall Height:
1.59'' (4 cm)
Overall Width:
3.77'' (9.6 cm)
Weight:
12.50 oz (354.0 g)
UPC:
092644690631
Additional Information
Warnings
  • Never use the meter on a circuit with voltages that exceed the category based rating of this meter.
  • Read, understand and follow all instructions, cautions and warnings attached to and /or packed with all test and measurement devices before each use.
  • Do not use the meter during electrical storms or in wet weather, and do not use the meter or test leads if they appear to be damaged.
  • Before each use verify meter operation by measuring a known voltage or current.
  • Always adhere to local and national safety codes. Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.